Unit=mm
‚j‚bF Products Measuring
Point
Nominal size
1/8"�`3/8" 8A�`10A
1/2"�`3/4"
15A�`65A
1"�`3"
80A�`200A
4"�`6"
250A�`300A
Pipe Fittings
Headers
Joint-headers
Mul-Tees
Outside
diameter at end
(OD)
�}0.1mm �}1%
Wall thickness at end
(T)
 
Either bigger�}0.2mm or �}10%
Manual weld type�F�}20%
Straight end length
(l)
+ Not specified
- 0.4mm
Thinning length
(J)
+ Not specified
- 0
Elbow
D-elbows
 
Minimum thickness other than end -35%  
Over tube Inside diameter at end
(ID)
 
�}0.2mm  - 
Elbows
Tees
J-Tees
Headers
J-headers
Mul-tees
Center to end
�iA,B,C,M)
�}0.8mm �}1.6mm �}2.4mm
D-elbows
D-Tees
Center to end
�iA,B,C,M)
�}1.6mm �}1.6mm �}2.4mm
Clean laps
Pipe flanges
Length
(FF,FP)
�}0.8mm �}1.6mm �}2.4mm
Caps
180�‹Return bends
Back to end
(E,BH)
�}0.8mm �}3.2mm
Reducers
Cap-reducers
J-reducers
J-caps
Outside-diameter-changeable fittings
Wall-thickness-changeable fittings
Over tube
Over all length
(H,Q,L)
�}0.8mm �}1.6mm �}2.4mm
D-Reducer Over all length
(H,Q,L)
�}1.6mm �}1.6mm �}2.4mm
Clean laps Thickness of lap (t) -
10A + 1.6mm
- 0mm
Diameter of lap (G) -
10A + 0mm
- 0.8mm
+ 0mm
- 1.6mm
Headers
J-Headers
Mul-tees
Length of end
(EL)
�}1.6mm
Branch pitch
(P)
�}1.6mm �}2.4mm
Total length
(L)
�}2.5mm
Helium leakage test value
�iApplication for welded products�j
Measuring instrument �F Ulvac HELIOT700
Detection sensitivity �F 1.0�~10-8Pa�Em3/sec
Pressure�Eairtightness test value
�iApplication for welded products/According to your requirement)
‡@ pressure test value �F 1.5MPa(15kg/‡p2)
‡A Airtightness test value �F 1.1MPa(11kg/‡p2)
Pressure test under higher pressure available at your option.